Shapeone®
Unique design,
different connections
High primary stability even in d4 bone
Platform switching . The platform switching connection occurs when the diameter of the prosthetic parts, emerging from the implant, is smaller than that of the implant platform. About 1 mm of the neck, 2.5 mm in version S1T and S1Tn (Unique) , which protects more from bacterial attacks in the machined version. Cutting coronal threads for a better force discharge on cortical bone to provide excellent stability even in a few millimetres. 55° triple thread over the entire body implant with a pitch of 1.8 mm (0.6 mm/thread); each turn allows going down of 1.8mm, speeding up the insertion phase. 3 aggressive apical cuts provide better primary stability while centering the implant and the possibility to change direction during its insertion. Apex aggressive but rounded to protect Schneider's membrane.
![]() |
![]() |
![]() |
![]() |
SHAPE ONE B INTERNAL HEX Bone level Surface treatment C ![]() S1B-C ![]() |
SHAPE ONE B INTERNAL HEX Bone level Surface treatment HYHA ![]() S1B-HYHA ![]() |
SHAPE ONE TN EXTERNAL HEX Bone or Tissue Level Surface treatment C ![]() S1TN ![]() |
SHAPE T INTERNAL OCTAGON Tissue Level Surface treatment C ![]() S1B-C ![]() |
![]() |
Main features 01 . Platform switching 02. About 1 mm of the neck which protects more from bacterial attacks in the machined version 03. Cutting coronal threads for a better force discharge on cortical bone to provide excellent stability even in a few millimeters of bone 04. 55° triple thread over the entire implant body with a pitch of 1.8 mm (0.6 mm/thread); each turn allows going down of 1.8mm, speeding up the insertion phase 05. 3 aggressive apical cuts provide better primary stability while centering the implant and the possibility to change direction during its insertion 06. Apex aggressive but rounded to protect Schneider's membrane |
Some details
threads, connections, platforms, hex and surface treatments
implant system | thread | connection | platform | hex | treatment |
ShapeOne B | Triple | internal hex | 3.5mm | 2.5mm | C – HYHA |
ShapeOne Tn | Triple | internal hex | 3.5mm | 2.5mm | C |
ShapeOne T | Triple | Internal octagon | 4.8mm | 3.1mm | C |
Diameters and heights
OR | ShapeOne B | ShapeOne Tn | ShapeOne T |
3.75 | h 8 | 10 | 11.5 | 13 | 16 mm | h 8 | 10 | 11.5 | 13 | 16 mm | h 8 | 10 | 11.5 | 13 | 16 mm |
4.1 | 6.5am | 8 | 10 | 11.5 | 13 | 16mm | h 4.5 | 6.5 | 8 | 10 | 11.5 | 13 | 16mm | h 4.5 | 6.5 | 8 | 10 | 11.5 | 13 | 16mm |
4.7 | 6.5am | 8 | 10 | 11.5 | 13 | 16mm | h 4.5 | 6.5 | 8 | 10 | 11.5 | 13 | 16mm | h 4.5 | 6.5 | 8 | 10 | 11.5 | 13 | 16mm |
Discover the other implant system
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
SHAPE ONE Conical self threading body with triple thread ![]() |
IMAX Fine double thread, conical apex, conical body ![]() |
IMAX MUA No connection between implant and abutment ![]() |
iMAX NHSIC Fine double thread, conical connection ![]() |
VOLUTION Large double thread, conical body ogiva design ![]() |
SHAPEMINI with ball connection in TIN or fixed abutment ![]() |