Surgical Protocol iMAX – Short Implant

SURGICAL PROTOCOL


Implant system
iMAX


heights from 4.5 to 6.5 mm


Connectors, drills, countersinks and taps


ShapeOne B

Connectors: HDH25S and HDH25L


Ø
Final drills (bone d4)
Final drills (bone d3-d2-d1)
Countersinks (bone d3-d2-d1)
Taps (bone d1)
3.7
D2833M
D3338M
CSD37
TAPiMAX37
4.1
D3338M
D3844M
CSD41
TAPiMAX41
4.7
D3844M
D4448M
CSD47
TAPiMAX47
5.2
D4448M
D4448M
CSD52
TAPiMAX52


iMAX NHSE

Connectors: HDH25S and HDH25L


Ø
Final drills (bone d4)
Final drills (bone d3-d2-d1)
Countersinks (bone d3-d2-d1)
Taps (bone d1)
3.7
D2833M
D3338M
CSD37
TAPiMAX37
4.1
D3338M
D3844M
CSD41
TAPiMAX41
4.7
D3844M
D4448M
CSD47
TAPiMAX47
5.2
D4448M
D4448M
CSD52
TAPiMAX52


ShapeOne T

Connectors: HDH25S and HDH25L


Ø
Final drills (bone d4)
Final drills (bone d3-d2-d1)
countersinks (bone d3-d2-d1)
Taps (bone d1)
4.1
D3338M
D3844M
CSD41
TAPiMAX41
4.7
D3844M
D4448M
CSD47
TAPiMAX47
5.2
D4448M
D4448M
CSD52
TAPiMAX52

Different phases of the insertion





Download our surgical protocol

Download (.pdf)